Features

Vessel Systems Monitor Tank Sender – Diesel, Water, Waste

  • Accurate – used with the Vessel Systems Monitor VSM 422 PN 1800—can be precisely calibrated for each tank*
  • Reliable – SSI Technologies, Inc. Fluid-Trac® is non-contacting eliminating any mechanical moving parts that can wear and cause intermittent or complete signal loss
  • Digital filtering – Eliminates errors due to liquids sloshing in mobile tanks
Limitations and considerations for mounting the ultrasonic tank senders:
  • Senders are calibrated to the VSM 422 and will not function with other monitors
  • Senders must be mounted 4″ or greater distance from a tank side or baffle
  • Tank floor must not be sloped
  • Tanks must not be deeper than 32″
  • Sender must be mounted perpendicular to the surface of the liquid
  • The sender negative connection should be connected as directly as possible to the main negative bus.

Specification

Vessel Systems Monitor Tank Sender – Diesel, Water, Waste 
Operating Current40mA @ 12V
45mA @ 24V
Supply Voltage10-32V DC
Weight0.11 kg
SKU BS-1810
Barcode # OEBC527505
Brand Blue Sea Systems
Shipping Weight 0.1200kg

Blue Sea Systems Vessel Systems Monitor Tank Sender - Diesel, Water, Waste

SKU: BS-1810
Sold out
Sale price
$250.00
RRP $256.00
Earn 2,500 Outback Rewards Points
Sale price
$250.00
DON'T PAY RRP $256.00
PayPal Checkout
4 payments of $62.50

afterpay More info.

Make 4 payments of $62.50 over 8 weeks and get it now!

zipMoney
From $10 / week
Afterpay
4 payments of $62.50

Calculate Shipping

Features

Vessel Systems Monitor Tank Sender – Diesel, Water, Waste

  • Accurate – used with the Vessel Systems Monitor VSM 422 PN 1800—can be precisely calibrated for each tank*
  • Reliable – SSI Technologies, Inc. Fluid-Trac® is non-contacting eliminating any mechanical moving parts that can wear and cause intermittent or complete signal loss
  • Digital filtering – Eliminates errors due to liquids sloshing in mobile tanks
Limitations and considerations for mounting the ultrasonic tank senders:
  • Senders are calibrated to the VSM 422 and will not function with other monitors
  • Senders must be mounted 4″ or greater distance from a tank side or baffle
  • Tank floor must not be sloped
  • Tanks must not be deeper than 32″
  • Sender must be mounted perpendicular to the surface of the liquid
  • The sender negative connection should be connected as directly as possible to the main negative bus.

Specification

Vessel Systems Monitor Tank Sender – Diesel, Water, Waste 
Operating Current40mA @ 12V
45mA @ 24V
Supply Voltage10-32V DC
Weight0.11 kg
SKU BS-1810
Barcode # OEBC527505
Brand Blue Sea Systems